Seven Nevada marijuana testing laboratories are warning state regulators that proposed changes to marijuana sampling procedures could allow contaminated products to pass laboratory testing, potentially exposing consumers to mold, pesticides and other contaminants.
In an eight-page position paper submitted to the Nevada Cannabis Compliance Board ahead of its October 15 hearing, the Coalition of Nevada Cannabis Independent Testing Laboratories outlined several concerns with proposed regulations implementing Senate Bill 157, which increased the maximum size of marijuana flower lots from five pounds to 15 pounds.
The submission, dated October 2 and formally transmitted October 13, was approved by 374 Labs, G3 Labs, MA and Associates, ERP, NV Cann Labs, RSR Analytical Laboratories and Digipath Labs.
At the center of the dispute is how laboratories collect and process samples intended to represent an entire 15-pound lot of marijuana. The proposed regulations require a minimum 60-gram sample, divided into three 20-gram portions for initial testing, possible retesting and retention.
The laboratories support that amount but argue that the entire 60 grams must first be ground and thoroughly mixed before being divided. Otherwise, they warn, the portion actually tested represents just 0.29% of the 15-pound lot, rather than the 0.88% represented by the complete composite sample.
The coalition argues that this distinction is particularly important because contaminants are not necessarily distributed evenly throughout marijuana flower. Mold, including Aspergillus, can develop in isolated areas, while pesticide residues may vary between individual plants and flowers.
According to a statistical analysis cited in the submission, when Aspergillus contamination is present at a prevalence of 3%, testing based on the smaller 0.29% sample coverage could fail to detect it 91% of the time.
The laboratories also raised concerns about provisions allowing marijuana cultivators to determine what happens to unused testing material after a sample passes. Under the proposed rules, the cultivation facility could choose whether the additional 40 grams reserved for retesting and retention are returned or destroyed.
The coalition argues that allowing cultivators to make this decision undermines laboratory independence and could eliminate the evidence needed to verify test results if questions arise later. Instead, the laboratories want testing facilities to retain those samples for at least 30 days, with longer retention required when complaints, investigations or additional testing are pending.
The submission also calls for uniform requirements governing how cultivators present marijuana lots for sampling. The laboratories warn that inconsistently sized containers and uneven sample collection could produce results that do not accurately reflect the marijuana being tested.
The concerns come after the Cannabis Compliance Board issued a public health and safety bulletin in September 2025 involving marijuana flower and pre-rolls that initially passed laboratory testing but subsequently failed microbial testing. State regulators said the products had been misrepresented during the original sampling process, prompting additional testing that identified yeast, mold or Aspergillus contamination.
The laboratories are requesting revisions before the new sampling rules are finalized, including mandatory homogenization of the complete sample, standardized collection procedures and stronger chain-of-custody protections.
If those changes are not made, the coalition wants Nevada to require warning language on laboratory certificates and marijuana product labels explaining that the testing sample may not accurately represent the entire lot.
The coalition argues that maintaining reliable testing standards becomes increasingly important as the amount of marijuana covered by a single laboratory result increases from five pounds to 15 pounds.